FACTORY EQUITMENT

We utilize the best materials and equipments and put 

cautious quality control and manufacturing management into 

practice under the guiding of ISO9002 to ensure our goal of 

"Total Quality Control."        

We monitor the temperature and humidity of the factory by 

the central A/C system to maintain the best working 

environment. We also introduce the automation system to 

process sealing, welding, semi-finished products 

inspecting, molding and finished products inspecting. We 

will continually strive for perfection.

SPECIFICATION
Standards CNS 4327, JIS C4908,
Capacity tolerance ( K ) ±10% ( U ) +10%--5% (J ) ±5%
Frequency 50 / 60Hz
Insulation resistance Terminals to case ( Above 2000 M. Ω )
Voltage withstand Between terminals W. VX1.5 One minute
Terminals to case W. VX2+1000 ( min. 2000 ) One minute
Dissipation factor MF TYPE Below 0.6%
MPP TYPE Below 0.1%
Range of temp MF TYPE -25oC ~ +60oC
MPP TYPE -40oC ~ +85oC
Sealing test Heating in 75±3oC ( 90±3oC ) for 15 minutes should not leak oil.
Continue life test W. V x 120% 1000±10hr
On-off life test W. V x 140% ( ON 2SEC / OFF 2SEC ) TEST CYCLE 100,000±1,000 TIMES


Fu-Jack Enterprise Corporation
No.79, Lane 258, Shoei Yuan Road, Feng Yuan, Taichung, Taiwan, R. O. C. 420
Tel:
886-4-25204703
Fax:
886-4-25228805
http://
www.taiwan-capacitor.com.tw/
taiwan.cap@msa.hinet.net